ADIC Scalar Series User Manual

Page 37

Advertising
background image

Equipment Description

27

Initialize Map Slots

Enables/disables the mapping of the storage slots whenever the Scalar Library is powered-up, after the front door
has been opened and then closed, or if a SCSI bus Reset occurs

p To disable the mapping of slots use the UP or DOWN keys to select "N". Press ENTER to execute the

change.

Note

Init Map Slots default setting is Y.

Note

Disabling Init Map Slots by selecting “N” will force Init Scan Barcodes
to “N” ( see below).

Initialize Scan Barcodes

Enables/disables the scanning of the cartridge barcodes whenever the Scalar Library is powered-up, or after the
front door has been opened and then closed. The application software overrides the setting of this parameter. If
Barcode Scanner configuration is set to No, Initialize Scan Barcodes is ignored, and the barcode reader is not
available to the application software.

p To disable the scanning of barcodes use the UP or DOWN keys to select "N". Press ENTER to execute the

change.

Note

Init Scan Barcodes default setting is Y.

Note

Enabling Init Scan Barcodes by selecting “Y” will force Init Map Slots
to “Y” ( see above).

Advertising