Drive power-on self-test – ADIC Scalar Series User Manual

Page 43

Advertising
background image

Operation and Maintenance

33

What Happens When Door is Opened

Whenever you open the front door of the Scalar Library , the following actions occur:

l

The library will return Unit Attention and Not Ready status to the host computer.

l

Any function, if executed, that would change the state of the robotics machine is disabled.

Resuming Operation

To resume normal operation, close the door and lock it.

After the door is closed:

l

The library will perform its power up checks.

l

The application software may update its own cartridge inventory.

Drive Power-on Self-Test

When you power up your Scalar Library , the DLT drives each perform a Power-on Self-Test (POST) while the
library is performing the Power Up Checks. The sequence of events for each drive is:

1. The LEDs on the right front panel of the drive will turn on sequentially from top to bottom. All

LEDs will remain ON for a few seconds.

2. The LEDs on the left front panel of the drive will turn ON at the same time for about three seconds

and then turn OFF.

3. The Operate Handle, Write Protected, and Use Cleaning Tape LEDs will turn OFF. The

Tape in Use LED will blink while the tape drive initializes.

4 If your external SCSI bus terminator has a Term Power LED it should also be illuminated.