Part 3 Controller Data Structure

1.3 Virtual I/O Ports

(1) Virtual input ports

Port No.

Function

7000 Always

OFF

7001 Always

ON

7002

Voltage low warning for system memory backup battery

7003

Abnormal voltage of system memory backup battery

7004

(For future expansion = Use strictly prohibited)

7005

(For future expansion = Use strictly prohibited)

7006

Top level system error = Message level error is present

7007

Top level system error = Operation cancellation level error is present

7008

Top level system error = Cold start level error is present

7009

(For future expansion = Use strictly prohibited)

7010

Drive source cutoff factor is present (including when waiting for cutoff reset input)

7011

Latch signal indicating that all operation cancellation factor is present (latch signal for recognizing
1-shot cancellation factor; latch is cancelled by 7300 being ON)

7012

All operation pause factor is present (including when waiting for restart switch signal. Valid only
during automatic operation recognition)

7013

All servo axis interlock factor is present (all operation pause factor + interlock input port factor)

7014

(For future expansion = Use strictly prohibited)

7015

Voltage low warning for axis 1 absolute data backup battery

7016

Abnormal voltage of axis 1 absolute data backup battery (latched until power on reset or software
reset)

7017

Voltage low warning for axis 2 absolute data backup battery (main application version 0.28 or later)

7018

Abnormal voltage of axis 2 absolute data backup battery (latched until power on reset or software
reset)

7019

Voltage low warning for axis 3 absolute data backup battery

7020

Abnormal voltage of axis 3 absolute data backup battery (latched until power on reset or software
reset)

7021

Voltage low warning for axis 4 absolute data backup battery

7022

Abnormal voltage of axis 4 absolute data backup battery (latched until power on reset or software
reset)

7023

Voltage low warning for axis 5 absolute data backup battery (valid only when the controller
supports up to 6 axes)

7024

Abnormal voltage of axis 5 absolute data backup battery (latched until power on reset or software
reset. Valid only when the controller supports up to 6 axes)

7025

Voltage low warning for axis 6 absolute data backup battery (valid only when the controller
supports up to 6 axes)

7026

Abnormal voltage of axis 6 absolute data backup battery (latched until power on reset or software
reset. Valid only when the controller supports up to 6 axes)

7027 ~ 7040 (For future expansion = Use strictly prohibited)
7041 ~ 7070 (For future expansion = Use strictly prohibited)

7071

In AUTO mode

7072

During automatic operation

7073 ~ 7100 (For future expansion = Use strictly prohibited)

7101

Running program No. 01 (including during pause)

~ ~

7164

Running program No. 64 (including during pause)

7165

Running program No. 65 (including during pause)
(Controller with increased memory size (with gateway function) only)

~ ~

7228

Running program No. 128 (including during pause)
(Controller with increased memory size (with gateway function) only)

7229 ~ 7299 (For future expansion = Use strictly prohibited)