437

Appendix

I/O Parameters

No. Parameter

name

Default value

(Reference)

Input range

Unit

Remarks

126 Network attribute 7

7D007D0H

0H ~

FFFFFFFFH

Ethernet TCP/IP message communication attribute
Bits 0 to 15:

Min timeout value (msec)

Bits 16 to 31: Mout timeout value (msec)

127 Network attribute 8

5050214H

0H ~

FFFFFFFFH

Ethernet TCP/IP message communication attribute
Bits 0 to 7:

CONNECT_TIMEOUT
(Change is prohibited)
(Setting of “0” is prohibited) (sec)

Bits 8 to 15:

Connection retry interval
(IAI protocol B/TCP) (sec)

Bits 16 to 23: Send timeout value (sec)
Bits 24 to 31: IAI protocol B-SIO non-communication

check timer setting (sec)
(IAI protocol B/TCP connection trigger)

128 Network attribute 9

10000H

0H ~

FFFFFFFFH

Ethernet TCP/IP message communication attribute
Bits 0 to 15:

SEL server open timeout value (sec)
(No timeout check when “0” is set)

Bits 16 to 23: Connection retry interval

(Tracking vision system I/F) (sec)

129 Network attribute 10

0H

0H ~

FFFFFFFFH

Ethernet operation requirement
Bits 0 to 3:

Modbus/TCP (Remote I/O)
(0: Not in use
1: Use (Disable exception status)
2: Use (Enable exception status (upper

two digits of error number)))

* Refer to the explanation of error

levels in the operation manual and
perform processing appropriate for
each error level.

Bits 4 to 7:

TCP/IP message communication
(0: Not in use, 1: Use)

Bits 8 to 31:

Reserved (Operation requirement)

130 Own MAC address (H)

0H

Reference

only (HEX)

Only the lower two bytes are valid.

131 Own MAC address (L)

0H

Reference

only (HEX)

132 Own IP address (H)

192

1 ~ 255

* Setting of “0” and “127” is prohibited.

133 Own IP address (MH)

168

0 ~ 255

134 Own IP address (ML)

0

0 ~ 255

135 Own IP address (L)

1

1 ~ 254

* Setting of “0” and “255” is prohibited.

136 Subnet mask (H)

255

0 ~ 255

137 Subnet mask (MH)

255

0 ~ 255

138 Subnet mask (ML)

255

0 ~ 255

139 Subnet mask (L)

0

0 ~ 255

140 Default gateway (H)

0

0 ~ 255

141 Default gateway (MH)

0

0 ~ 255

142 Default gateway (ML)

0

0 ~ 255

143 Default gateway (L)

0

0 ~ 255

Advertising