Part 4 Commands

z TMLI (Dedicated SCARA command: Move relatively between positions on tool coordinate system via

interpolation in CP operation)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,
declaration

Operand 1

Operand 2

Output

(Output, flag)

Optional Optional TMLI

Position

number

Prohibited PE

[Function] Each axis will move relatively on the tool coordinate system with interpolation (= CP

operation) based on the position data specified in operand 1 setting the travel amount from
the current position.

(Note 1)

This command is used exclusively for SCARA axes. If it is specified for a linear movement
axis, an “Error No. B80, Specification-prohibited axis error” or “Error No. 421, SCARA/linear
movement axis simultaneous specification error” will generate.

(Note 2)

Repeated use of incremental (relative) movement commands will accumulate coordinate-
conversion rounding errors.

[Example] TMLI

120

Position data

Tool coordinate home
after movement

Tool coordinate home
before movement

Yt1

Yt1

-Yt1

30

60

-30

q

Xt1

Xt1

Advertising