IAI America XSEL-QX User Manual

Page 463

Advertising
background image

439

Appendix

I/O Parameters

No. Parameter

name

Default value

(Reference)

Input range

Unit

Remarks

201 Attribute 1 of SIO

channel 1 opened to
user (mount standard)

28100000H 0H

~

FFFFFFFFH

Bits 28 to 31: Baud rate type (0: 9.6, 1: 19.2, 2: 38.4, 3:

57.6, 4: 76.8, 5: 115.2 kbps)
* If flow control is performed, specify 38.4

kbps or less
Specifying a higher baud rate may
generate an overrun error, etc.

Bits 24 to 27: Data length (7 or 8)
Bits 20 to 23: Stop bit length (1 or 2)
Bits 16 to 19: Parity type (0: None, 1: Odd, 2: Even)
Bits 12 to 15: For future extension
Bits 8 to 11: For future extension
Bits 4 to 7:

For future extension

Bits 0 to 3:

Use selection (0: Do not use, 1: Use)
* Used on the application level.

202 Attribute 2 of SIO

channel 1 opened to
user (mount standard)

00000001H 0H

~

FFFFFFFFH

Bits 28 to 31: For future extension
Bits 24 to 27: For future extension
Bits 20 to 23: For future extension
Bits 16 to 19: Character send interval (msec)
Bits 12 to 15: Communication method (0: Full-duplex, 1:

Half-duplex)

Bits 8 to 11: Send operation type in half-duplex

communication
(0: Do not check CTS-ON at send
1: Check CTS-ON at send)

Bits 0 to 7:

Minimum receive

o send switching delay

in half-duplex communication (msec)

203 Attribute 3 of SIO

channel 1 opened to
user (mount standard)

01118040H 0H

~

FFFFFFFFH

Bits 28 to 31: Flow control type

(0: None, 1: Xon/Xoff, 2: Hardware)
* Valid only in full-duplex communication.
* If flow control is performed, specify 38.4

kbps or less
Specifying a higher baud rate may
generate an overrun error, etc.

Bits 24 to 27: Xon send selection when send after SIO-

CPU reset is enabled
(0: Do not send, 1: Send)
* Valid only in full-duplex communication

with Xon/Xoff flow control.

Bits 20 to 23: Send enable selection when the port is

open
(0: Disable, 1: Enable)
* Valid only in full-duplex communication

with Xon/Xoff flow control.

Bits 16 to 19: Xon/Xoff send selection when the port is

closed
(0: Do not send, 1: Send Xon, 2: Send
Xoff)
* Valid only in full-duplex communication

with Xon/Xoff flow control.

Bits 8 to 15: Flow control high limit (byte)
Bits 0 to 7:

Flow control low limit (byte)

* If the specified value satisfies the condition “Flow

control low limit

t SCI receive buffer size - flow control

high limit,” both the flow control high limit and low limit
will be replaced by values corresponding to 1/4 of the
SCI receive buffer size before the applicable
processing is performed.

Advertising