NOTE: K value is:

2000 mm/s if the calculated value of S is ≤ 500 mm

1600 mm/s if the calculated value of S is > 500 mm


When devices with > 40 mm resolution are used, the height of the top
beam has to be ≥ 900 mm (H2) from machine supporting base while
the height of the bottom beam has to be ≤ 300 mm (H1).
If the safety light curtain must be mounted in a horizontal position
(Fig.4), the distance between the dangerous area and the most
distant optical beam must be equal to the value calculated using the
following formula:

S = 1600 mm/s (t

1

+ t

2

) + 1200 – 0.4 H

where:

S = Minimum safety distance in mm.
t

1

= Response time of the ESPE in seconds

(see section 10 “Technical data”)

t

2

= Machine stopping time in seconds.

H = Beam height from ground. This height must always be less than
1,000

mm.


Fig. 4