No no – IDEC SG4 Type 4 Finger & Hand User Manual

Page 24

Advertising
background image

SG4-B Series

Instruction Manual

20

2.2.4. Emitter and receiver orientation

The two units shall be assembled parallel each other, with the beams
arranged at right angles with the emission and receiving surface, and
with the connectors orientated towards the same direction.

The configurations shown in Fig.10 must be avoided:


Fig. 10

2.2.5. Use of deviating mirrors

The control of any dangerous area, with several but adjacent access
sides, is possible using only one safety device and well-positioned
deviating mirrors.
Fig.11 shows a possible solution to control three different access
sides, using two mirrors placed at 45° respect to the beams.


Fig. 11