 The ground connection of the two units is not necessary for Class

III, while the use of a duly-insulated low-voltage feeder type SELV
or PELV is compulsory. In this case, we recommend covering the
earth symbol present on the caps of the two units with a blank
sticker.

 The ground connection of the two units is compulsory for Class I,

while the use of a duly-insulated feeder type SELV or PELV is not
compulsory but anyway recommended.

The following table is a summary of SG4 electrical protections.

Electrical protections

Class I

Class III

Ground Connection

Compulsory

Not necessary

Ground connection symbol

Compulsory

Not necessary

Power supply by generators
SELV / PELV

Recommended Compulsory