SG4-B Series

Instruction Manual

34

The standard installation described hereinafter is the one shown in
Fig. 22, i.e. with the bar assembled with the connectors pointing
down.

5.1. Correct alignment procedure

The light curtain alignment can be effected only after having
completed the mechanical installation and the electrical connections
as described above. Compare alignment results with those given in
the following table.

NOTE: To enter alignment mode connect the device as described in
section 6.5 “Alignment aid function”.

Display

LED

NORMAL

OP.

LED

SAFE

(BREAK)

LED

yellow

SYNC

LED

yellow

LAST

Condition

Alignment

status

ON

Sync NOK
Last NOK

OFF

ON

Sync OK
Last NOK

OFF ON

OFF OFF

Sync OK
Last NOK

Middle optics NOK

Not

aligned

ON OFF OFF

OFF

Each beam is over

the min. operating

threshold and the

number of beam over

the threshold is

included between

0 and 25%

MINIMUM

align.

ON OFF OFF

OFF

Each beam is over

the min. operating

threshold and the

number of beam over

the threshold is

included between

25 and 50%

ON

OFF

OFF

OFF

Each beam is over

the min. operating

threshold and the

number of beam over

the threshold is

included between

50 and 75%

ON

OFF

OFF

OFF

Each beam is over

the min. operating

threshold and the

number of beam over

the threshold is

included between

75 and 100%

MAXIMUM

align.