3. MECHANICAL

MOUNTING

The emitting (TX) and receiving (RX) units must be installed with the
relevant sensitive surfaces facing each other. The connectors must be
positioned on the same side and the distance must be included within
the operating range of the model used (see section 10 “Technical
data”).

The two units must be positioned the most aligned and parallel
possible.
The next step is the fine alignment, as shown in section 5 “Alignment
Procedure”.

Two types of brackets can be used to fix the two units:

Angled fixing brackets
Angled fixing brackets are supplied with all SG4-B models (Fig.13).
Adjustable supports for correcting unit inclination on the axes are
available on request (see section 14 “Accessories”).

For fixing with angled brackets, refer to Fig.13.

Fig. 13