Fig. 12


 ESPE has to be correctly aligned, press slightly on the product side

in both directions the red LED must not turn on

.

 The activation of the TEST function causes the opening of the

OSSD outputs (red LED

on and controlled machine stop).

 The response time at machine STOP, including the ESPE and

machine response times, must be included in the limits defined in
the calculation of the safety distance (refer to section 2 “Installation
modes

”).

 The safety distance between the dangerous parts and ESPE must

comply with the requirements indicated in section 2 “Installation
modes

”.

 A person must not access or remain between ESPE and the

dangerous parts of the machine.

 Access to the dangerous areas of the machine must not be

possible from any unprotected area.

 ESPE must not be disturbed by external light sources, ensuring that

it remains in Normal operating function for at least 10-15 minutes
and placing the specific test piece in the protected area in the SAFE
condition for the same period.

 Verify the correspondence of all the accessory functions, activating

them in the different operating conditions.