IDEC SG4 Type 4 Finger & Hand User Manual

Page 46

Advertising
background image

SG4-B Series

Instruction Manual

42

Function

Type

Check and repair

LED

DIGIT

OSSD error
(red ON)

Check OSSD
connections. Make
sure that they are not
in contact with one
another or with the
supply cables, then
Reset. If the failure
continues contact
DATASENSOR

Internal error
(red ON)

Switch OFF and switch
ON the power supply
circuit. If the failure
continues contact
DATASENSOR

Optical error
(red ON)

Reset. If the failure
continues contact
DATASENSOR

EDM error
(red ON)

Check EDM
connections and lines.
If the failure continues
contact
DATASENSOR

Restart selection
error
(red ON)

Check the man/auto
restart connection. If
the failure continues
contact
DATASENSOR

Error status

No power supply
(LEDs OFF)

Check connections
and input voltage
value. If the failure
continues contact
DATASENSOR