IDEC SG4 Type 4 Finger & Hand User Manual

Page 42

Advertising
background image

SG4-B Series

Instruction Manual

38

6.4. EDM function

The light curtain has a function for monitoring
actuation external devices (EDM). This function
can be enabled or deactivated.

EDM enabled:
- Disconnect or connect to the ground pin 3 of

receiver M12 8-pole connector (EDM enabling
= ON).

- Connect EDM input (pin 4 of M12 8-pole –

RX) to a 24 VDC normally closed contacts of
the device to be monitored.

NOTE: The decimal dot on the display shows that the function is
enabled.

EDM deactivated:
- Connect to 24 VDC pin 3 of receiver M12 8-pole connector (EDM
enabling = OFF).
- Disconnect or connect to the ground EDM input (pin 4 of M12 8-
pole - RX).
This function checks normally closed contact switch on OSSD status
change.


T

C

 350 msec: 350 msec: time after OSSD OFF-ON switch when

EDM test is performed.

T

0

 100 msec: time after OSSD ON-OFF switch when EDM test is

performed.

Advertising