Probe Settings
Teledyne LeCroy
7. Select Recording Options and click the Probe Settings tab.
8. Click Auto Configure to display the Calibrate SummitT3‐8 Dialog.
Manually set the polarity for each lane in this dialog with the polarity settings in the
Link Dashboard. Link Width, Speed and Polarity must be set the same as the current
state of the link. Checking the Quick Calibration option will sweep through the CTLE
setting only. If unchecked it will sweep through both CTLE and DFE. Using Detect Idle
Errors will increase the calibration time but it will improve/optimize calibration
results.
Figure 5.59: Calibrate Summit T3-8 Dialog
9. Click Start Calibration
On completion of calibration, close the Auto Configure dialog.
It may take 10‐20 minutes for x8 and upwards 45 minutes to calibrate an X16 link for
both directions with Detect Idle Errors checked and Quick Calibration unchecked.
10. You can now start recording at Gen3 speed using the Recording Option Speed set to
Gen3 or Auto.