Connecting the probe data cable, 9 using probes, Components – Teledyne LeCroy Summit T3-8 PCIe Multi-lane Protocol Analyzer User Manual User Manual
Page 29
Summit T3‐8 PCI Express Multi‐Lane Protocol Analyzer User Manual
17
Using Probes
Teledyne LeCroy
Connecting the Probe Data Cable
x8 recordings require one cable. To connect a single Interposer data cable, connect the
probe data cable to the Interposer card at [7:0]. Connect Side A of the probe cable to the
Upstream [7:0] port on the Analyzer, and connect Side B of the probe cable to the
Downstream [7:0] port.
3.9 Using
Probes
3.9.1
Example: Connecting the Summit T3-8 Analyzer to the Device Under Test
Using a Gen3 MidBus Probe
Note:
Mid‐bus probes require attachment‐pad and reference‐clock connections. For information
about how to connect the attachment pad, reference clock, and cables in your system, see the
MidBus Probe Manual.
Components
Figure 3.12: iPass Y-cable
Figure 3.13: MidBus Probe Pod