Input Circuit Drawings

‹ Internal Circuit

‹ Wiring

indicates a fuse.

indicates load.

• Since the output terminals are not electrically protected, an output line might be shortcir-

cuited or a connection fault might damage this product. Please install an applicable fuse to
prevent an overload in the circuit, if necessary.

Maximum Load
Voltage

Per Channel

0.3 A

0.1 A

Per Common 3 A

1 A

Output Protection Type

Output is unprotected

Output Voltage Drop

1 VDC or less (voltage between COM and output
terminals when output is on)

Clamp Voltage

39 VDC ±1 V

Voltage Leakage (when OFF)

0.1 mA or less

Output Delay
Time

OFF-ON

300 µs or less

ON-OFF

300 µs or less

Isolation Method

Between output terminals and internal circuit:
photocoupler isolated
Between output terminals: not isolated

External Connection

10-pin terminal
connector

MIL connector

EXM-DDO8TT

EXM-DDO16TK

Internal
Circuit

Output

L

<EXM-DDO8TT>

<EXM-DDO16TK>

Q0

0

Q1

1

Q2

2

Q3

3

Q4

4

Q5

5

Q6

6

Q7

7

COM(+)

-V

20 Q0

Q1

Q2

Q3

Q4

Q5

Q6

Q7

COM(+)

2

-V

Q8

19

Q9

Q10

Q11

Q12

Q13

Q14

Q15

COM(+)

-V

1