6 2-ch analog-input module – Proface AGP3500 - 10.4 DIO HMI" User Manual

Page 24

Advertising
background image

24

15.6 2-ch analog-input module

The detail of the external power supply is: the rated supply voltage is 24 VDC, the rated
input voltage ranges from DC20.4 to 28.8 V The consumption current is 35 mA

*1

or

40 mA

*2

(24VDC) when the input is not-open, output 100%. You can select either voltage or

current for each input channel.

EXM-AMI2HT

Characteristics of Analog Voltage Inputs Voltage Input

Current Input

Input Range

From DC0 to 10 V

From DC4 to 20 mA

Input Impedance

1 M

 min.

10

Input Points

2 points

A-D
Conversion

Sample Repetition Time

20 ms max.

Total Input System Transfer
Time*

3

105 ms + 1 scan time*

1

60 ms +1 scan time*

2

Input Type

Single-ended input

Differential input

Operating Mode

Self-scan

Conversion Mode

 type ADC

Input Error Maximum Error at 25°C

(77°F)

±0.2% of full scale

Temperature Coefficient

±0.006% of full scale/°C

Repeatable after
Stabilization Time

±0.5% of full scale

Nonlinear

±0.2% of full scale

Maximum error

±1% of full scale

Data

Digital Resolution

4096 increments (12 bits)

Input Value of LSB

2.5 mV

4 µA

Data Type in Application
Program

0 to 4095 (12 bit data)
-32768 to 32767 (optional range designation)*

4

Monotonicity

Yes

Input Data Out of Range

Detectable*

5

*

6

Noise
Resistance

Maximum Temporary
Deviation during Electrical
Noise Tests

±3% maximum

*1

or ±1% maximum

*2

when a

1 kV clamp voltage is applied to the I/O wiring
and 1 kV is applied to the power directly.

Common Mode
Characteristics

Common mode reject ratio (CMRR): -50 dB

Common Mode Voltage

16 VDC

Input Filter

No

Cable

Twisted-pair shielded cable is recommended
for improved noise immunity

Crosstalk

2 LSB max.

Voltage Endurance

500 V between input and power circuit

Isolation Method

Photocoupler Isolation between input and
internal circuit