Chapter 3 PS-A Monitoring Features

3-7

‹ External Output Signal

The PS-A’s RAS interface connector uses the following output signals.

General-Purpose Output (DOUT 2 bits)

This general purpose digital output signal provides system condition information to external devices.

The System Monitor property of the control panel or the API-DLL is used by applications to control this signal.

The above mentioned general purpose digital output signals provide system condition information to

external devices.

The System Monitor property can be used to enable or disable any of these output signals.

• General-Purpose Input (DIN) level must be 1.5 seconds or longer to be detected.

It may not detect under 1.5 seconds.

• Be sure the voltage value between terminals is controlled via the input voltage, so

that the PS-A is operated within its recommended range. If the input voltage

exceeds this range, a malfunction or PS-A damage may occur.

• With Sink/Source input, even if the D(-), and RESET(-) are positive, and D(+),

RESET(+) are negative, no problems are created. Be sure to operate the unit within

the recommended voltage range.

For connection pin location details,

Rated Voltage

DC12V to 24V

Maximum Load Current

120mA/point

Out Voltage Drop

1.5V or less (at 100mA load current)

Output Points

2 points

Isolation Method

Photocoupler Isolation

Dielectric Strength Voltage

500V or more

External Power Supply

DC12V / 100mA

SEE

PS-3650A/PS3651A Hardware Manual 2 Specifications