8 setup guide for the system monitor property, 8 setup guide for the system monitor property -28, Setup guide for the system monitor property – Proface APL3000B - Node Box PC User Manual

Page 79: 28 3.8 setup guide for the system monitor property

Advertising
background image

PS-3650A / PS-3651A Reference Manual

3-28

3.8

Setup Guide for the System Monitor Property

The System Monitor Property allows you to specify PS-A items you want to monitor with the RAS features

and the notification method used when errors/alerts occur. When an error/alert occurs, notification is provided

according to the method specified in the System Monitor Property.

The following table lists the operating settings that can be configured for each feature.

O: Setting available X: Setting not available

The following table lists the default settings of each feature.

O: Setting X: Not set X: Not applicable

For procedure to set up the System Monitor Property, refer to the following section.

You can check the status of the PS-A unit you are monitoring with the RAS features on the

System Monitor screen.

For details regarding the System Monitor screen, refer to the following.

Feature

Operation

Buzzer

Popup

Message

OS

Shutdown

LED

DOUT

0, 1

*2

Reset

Timeout

(sec):

Watchdog Timer

O

O

O

O

O

O

O

Voltage O

O

O

O

O

X

X

Fan

*1

*1:

Nothing is displayed on PS-3651A.

O

O

O

O

O

X

X

Temperature

O

O

O

O

O

X

X

SMART

O

O

X

O

O

X

X

DIN0, 1

*2

*2:

Nothing is displayed on PS3650A-T42S / PS3651A-T42S.

O

O

O

O

O

X

X

Remote Reset

*2

X

X

X

X

X

O

X

Backlight

O

O

X

O

O

X

X

• Administrator Authentication is required for executing SMART Monitoring. When a

user who does not have the administrator authentication logs in, nothing is

displayed in the item of SMART.

Feature

Operation

Buzzer

Popup

Message

OS

Shutdown

LED

DOUT

0, 1

*2

Reset

Timeout

(sec):

Watchdog Timer

X

O

X

O

X

X

O (5sec)

Voltage X

O

X

O

X

-

-

Fan

*1

*1:

Nothing is displayed on PS-3651A.

X

O

X

O

X

-

-

Temperature

X

O

X

O

X

-

-

SMART

X

O

-

O

X

-

-

DIN0, 1

*2

*2:

Nothing is displayed on PS3650A-T42S / PS3651A-T42S.

X

O

X

O

X

-

-

Remote Reset

*2

-

-

-

-

-

X

-

Backlight

X

O

-

O

X

-

-

SEE

3.3.2 Setup Procedure (page3-11)

SEE

3.9 Setup Guide for the System Monitor Screen (page3-34)

Advertising