Monitor display switching and group selection, Contents of the status bar – Yokogawa Standalone MW100 User Manual

Page 180

Advertising
background image

3-58

IM MW100-01E

Monitor Display Switching and Group Selection

Select the Display Group

Select the display group you

wish to display.

Select message

Select a message to write.

1 to 5 messages can be set in advance.

Select a Monitor Display

Select a monitor display type.

• Overview

• Meter

• Bar graph

• Digital

• Trend

Free message box

Text can be entered when Free is selected

in the message selection list.

Message button

Writes the selected message.

Manual sample button

Performs a manual sample.

Writes data to the manual sample file from the CF card.

Data View button

Displays alarm summaries, manual samples, or reports

in a separate window.

Select a Background Color

Switch background color between white and gray.

Contents of the Status Bar

Memory capacity of the CF card

Used space (%) displayed with a green bar.

When the CF card is not installed,

the Ejected display appears.

Measurement group recording operation (1 to 3)/

thinning recording operation status (T)/

report recording operation status (R)

Recording: Yellow

Trigger wait state: Green

Stop state: Gray

MATH processing performance

(with the /M1 option or when a pulse input module is installed)

When computation processing reaches 100%, data loss occurs.

MW100 serial number

MW100 firmware version

3.16 Measured Data Monitor Display/Settings