App index – Yokogawa Standalone MW100 User Manual

Page 232

Advertising
background image

5-19

IM MW100-01E

Specification

1

2

3

4

5

App

Index

HTTP function:

Enables entry of settings on the MW100, starting and stopping
of measurement, computation, and recording, and real time
monitoring of measured and computed values using a Web
browser, as well as acquisition of CF card files using WebDAV.

RS-232 Interface (/C2 Option)

Connection method: Point-to-point
Communications:

Full-duplex

Synchronization:

Start-stop synchronization

Baud rate:

1200, 2400, 4800, 9600, 19200, 38400, 57600, or 115200 bits

Start bit:

1 bit, fixed

Data length:

Select either 7 or 8 bits

Parity:

Select even, odd, or none.

Stop bit:

Select either 1 or 2 bits

Hardware handshaking: RS-CS can be used
Software handshaking: X-ON, X-OFF can be used
Receive buffer length: 2047Byte
Protocol:

Dedicated protocol and Modbus/RTU

Communication services: Send/receive setting values, send/receive measured and

computed values.

RS-422A/485 Interface (/C3 Option)

Connection method: Multi-drop: 4-wire 1: 32, 2-wire 1: 31
Communications:

Half-duplex

Synchronization:

Start-stop synchronization

Baud rate:

Select 1200, 2400, 4800, 9600, 19200, 38400, 57600, or 115200 bps

Start bit:

1 bit, fixed

Data length:

Select either 7 or 8 bits

Parity:

Select even, odd, or none.

Stop bit:

Select either 1 or 2 bits

Receive buffer length: 2047Byte
Protocol:

Dedicated protocol and Modbus/RTU

Communication services: Send/receive setting values, send/receive measured and

computed values.

Communication Input Function

All settings on the main unit other than dip switch operation can be performed with
communication commands. For information about communication commands, see the
MW100 Communication Command Manual (IM MW100-17E).

5.2 Main Module (MW100-E) Specifications

Advertising