App index – Yokogawa Standalone MW100 User Manual

Page 236

Advertising
background image

5-23

IM MW100-01E

Specification

1

2

3

4

5

App

Index

Register Assign (Modbus Server Functions and Sharing)

Coil

*

Data

Data type

00001

Data on communication input channel C001

Bit

00002

Data on communication input channel C002

Bit

|

|

|

00300

Data on communication input channel C300

Bit

Communication input channel coils are 0 (Off) when data is zero, infinite (+Inf, –Inf), or

NaN, and 1 (On) when data is one or non-infinite.

* Firmware version R3.03 or later

Input Relay

*

Data

Data type

10001

Data on measurement channel 001

Bit

10002

Data on measurement channel 002

Bit

|

|

|

10060

Data on measurement channel 060

Bit

Input relays of measurement channels are 0 (Off) when data is zero, infinite or of a special

value (+Over, –Over, Skip, No Channel, Error, Invalid, or Lack), and 1 (On) when data is

one or non-infinite.

13001

Data on MATH channel A001

Bit

13002

Data on MATH channel A002

Bit

|

|

|

13300

Data on MATH channel A300

Bit

Input relays of MATH channels are 0 (Off) when data is zero, infinite or of a special value

(+Over, –Over, Skip, No Channel, Error, Invalid, or Lack), and 1 (On) when data is one or

non-infinite.

18001

Measuring

Bit

18002

Computing

Bit

18003

Recording

Bit

18004

Alarm occurring

Bit

18005

Waiting to confirm alarm status

Bit

Input relays indicating mode information are 1 (On) during operation in the relevant mode,

and 0 (Off) when stopped.

* Firmware version R3.03 or later

Input Registers

Data

Data Type

30001

Lower byte of measured data of measurement channel 001

Int 32

30002

Upper byte of measured data of measurement channel 001

|

|

30119

Lower byte of measured data from measurement channel 060

30120

Upper byte of measured data from measurement channel 060

• No decimal place information

31001

Lower byte of measured data from measurement channel 001

Float

31002

Upper byte of measured data from measurement channel 001

|

|

31119

Lower byte of measured data from measurement channel 060

31120

Upper byte of measured data from measurement channel 060

• Includes decimal place information.

32001

Alarm status of measured data of measurement channel 001

Bit string

|

|

32060

Alarm status of measured data of measurement channel 060

• Register structure and alarm status values

Alarm

2

1

4

3

4 bits

4 bits 4 bits 4 bits

0: No alarms

2: Lower limit alarm occurs

4: Differential lower limit alarm occurs

6: Lower limit on rate-of-change alarm occurs

8: Delay lower limit alarm occurs

1: Upper limit alarm occurs

3: Differential upper limit alarm occurs

5: Upper limit on rate-of-change alarm occurs

7: Delay upper limit alarm occurs

5.2 Main Module (MW100-E) Specifications

Advertising