SABINE Graphi-Q2 3122-S User Manual

Page 29

Advertising
background image

28

S

ECTION

E

IGHT

: U

SING

GRQ2 R

EMOTE

S

OFTWARE

CAUTION

FBX / Parametric Bypass

Be careful when bypassing FBX or
Parametric filters. This may allow
suppressed feedback to be released!
Bypass settings are saved in Stored
Presets and will be recalled as part of
a saved preset. Bypass switching,
however, is NOT subject to linked
control (see next section).

required to synchronize the arrival of multiple sound sources (all at different positions) to a listener will
vary as a function of temperature. The temperature gauge allows you to measure the distance you are
compensating for, and to adjust the corresponding delays as a function of ambient temperature. Simply
set temperature in Fahrenheit or Centigrade scales, either by clicking in the temperature field and entering
a value, or by clicking and dragging on the “mercury” in the thermometer icon. The relationship between
distance and milliseconds will be automatically set to the correct proportion for the specified temperature.

8.2.9. Bypass

The Graphi-Q2 Remote Control software offers expanded control over various bypass
functions. The Bypass controls are located at the bottom of the main screen, and are
activated by clicking the appropriate bypass boxes. Active front panel units will display
the appropriate bypass status as well.

The Remote Control allows all Graphi-Q2 processing to be bypassed individually by
function and/or by channel. Use Bypass to customize the processing you need on each
Graphi-Q2 channel.

For single channel Graphi-Qs, bypass controls apply to the two different outputs of the unit.
In addition to the choice of Bypass or Active for each function for each output, you may
set different values for delay time and output gain for Outputs A and B.

8.2.10. Front Panel Control Options

The new Graphi-Q2 allows you to selectively lock out each of the front panel control sections. You can,
for example, allow a guest engineer to use the graphic EQ while locking out the compressor and FBX
controls. The factory default is all front panel controls are enabled, and you can always go back to this
condition by loading preset number 1 - Front Panel Control.

The window below shows the Front Panel Options control. Simply check the functions you wish to be
controlled by the front panel and hit Apply. Control is unique to either the front panel or the Remote Control
software, but not both simultaneously.

Advertising
This manual is related to the following products: