SABINE Graphi-Q2 3122-S User Manual

Page 31

Advertising
background image

30

S

ECTION

E

IGHT

: U

SING

GRQ2 R

EMOTE

S

OFTWARE

RANGE LIMITS If changing cell values within a REL group causes some or all of the linked cell values
to reach and exceed the limits of available range, the initial offset will be reduced due to a “ceiling” (or
“floor”) effect. Once all REL cells reach their limit, all initial differences will disappear, and the group will
effectively act as an ABS group from that time forward.

8.3.1. How To Set Linked Groups

Use F11 or the Options Menu to access the Link Table. Choose the parameter you wish to link, and
choose the first cell in your linked group. Highlight the cell with your mouse, then type either A1 (for ABS)
or R1 (for REL) and hit the ENTER key. Do the same for the other cells you wish to add to your group,
then repeat the process for additional linked groups, using the code A2, R2, etc., up to eight linked groups
for each parameter. NOTE: Whenever an ABS group is set, the first cell chosen will act as the source
value to be copied to all other ABS cells with the same number code
. When you first establish your
ABS group, this cell will be highlighted in red. After the initial linking, all values will be the same.

8.3.2. Special Linking Considerations

8.3.2.1. GRQ3121 and GRQ3121-S units

Both models of the Sabine Graphi-Q2 that offer one channel input provide two independent outputs (see
Section 5.5). This is a very useful feature that enables a single input unit to emulate two-channel
operation, with additional control over the two outputs accessible with the Sabine GRQ2 Remote
Software. All parameters can be set to separate values for each of the two outputs (unless of course
they are linked using the Link Table). In other words, these outputs act independently, just like they do
in te GRQ3122 and GRQ3122-S.

8.3.2.2. Bypass Linking

Bypass/Active status for all parameters is NOT included under the control of linked cells. In other words,
bypass must be set for each channel of each unit manually. This affords more options for independent
control of the two outputs of single input units, since you may elect to apply processing or not to each
output (even though the settings for the processing may not be changed for the two outputs). For
example, you could set up two different EQ curves for each output of a GRQ3121, by using graphic EQ
settings applied to one output (and bypassed in the second), and using parametric EQ settings for the
second output (bypassing the first).

8.3.2.3. FBX Filter Linking

Since feedback involves an interaction of speaker and microphone, FBX filtering is most accurate on a
speaker-by-speaker, channel-by-channel basis. Linking FBX filters could end up applying filtering to one
channel better suited to another. Therefore, FBX filters cannot be linked—either from one unit to another,
or across same-unit channels for GRQ3122 and GRQ3122-S models. For GRQ3121 and GRQ3121-S
models (one in and two out), FBX filters will be identical for outputs A and B. You may bypass FBX in
either, both or neither of the outputs.

8.3.2.4. Parametric Filter Linking

Parametric filters can be linked, as shown below..

1.

The simplest case occurs when you begin by setting all the filters you wish to be linked for all linked
channels on all
affected units to Parametric prior to any other manipulation (see Section 8.2.5).
If you desire a REL link, set the frequencies, depths, and widths to independent values, then use
the Link Table to create a REL LINK group. If you desire an ABS link, use the Link Table to create
an ABS LINK group. Note that FBX filters in place always take precedence over corresponding
Parametric filters in a linked network, to prevent unintentional removal of an FBX filter.

2.

A more complicated scenario involves linking one channel to another without first setting
corresponding filter types on other channels or units to Parametric. You must manually change ALL
filters you wish to link to Parametric, and then change either width, depth, or frequency of any filter.

For the GRQ3121 and GRQ3121-S: You can have coresponding output filters set to different filter types.
As explained in section 8.3.2.1 above, independent settings are allowed on these 1x2 units.

Advertising
This manual is related to the following products: