35

B2-GRQ-2-OpGuide-v1-060519.pmd

S

ECTION

E

IGHT

: U

SING

GRQ R

EMOTE

S

OFTWARE

THERE IS NOT A BIG DIFFERENCE IN DELAY SETTINGS FROM ONE MEMORY TO THE NEXT.
Loading a new preset with a different delay setting will cause a temporary pitch shift in the audio
program if the change is made during program.

6.

An X will appear to indicate last saved and last loaded presets. Clicking in the program name region
will allow you to type in any name for your memory, up to 14 characters long. The number of the last
saved and loaded presets will appear at the bottom of the main Remote Control screen.

7.

The controlling interface (front panel or remote) will be indicated at the lower right of the main Remote
Control screen at all times.

8.

See Section 6.8 for information about changing default values for front panel operation for
parameters that are not accessible without Remote Control.

8.6.1.3. Saving Graphi-Q2 files externally

Use the File Menu at the top left of the Graphi-Q main screen for access to storage and recall of files
on your computer (hard drive, floppy disc, flash drive, etc.). Storing these presets as files on your
computer allows for moving them between Graphi-Qs and for creating backups of your work. When saving
to a location outside the Graphi-Q2 itself, you’ll need to name the file (Choose the File Menu, then Save
the Current Preset to a Disk File) using the suffix “.grq” and choose a storage location. Recall your files
by choosing the File Menu, then Load a Single Preset From a Disk File. You can track progress in loading
and saving by observing the progress bar in the lower left part of your screen.

When a file has been loaded into a Graphi-Q2’s memory from an external source, the bottom of the Main
Screen will indicate “FILE” as the last loaded memory. The Stored Presets screen will NOT show any
“X” under the Last Loaded column, indicating that the source of the last loaded preset was not an internal
Graphi-Q2 memory. However, if you quit the Remote Software and relaunch the program without first
saving and reloading a File in Graphi-Q2 memory (see section 8.6.1.1), the settings from the loaded file
will remain in place, but the Last Loaded indicators will revert to show the last memory loaded from internal
Graphi-Q storage.

When loading an external preset created on a GRQ3122 into a GRQ3121 you must remember that
although the GRQ3121 has two outputs, most of the parameter settings can only be set to identical values
for both outputs. For these parameters, the setting for channel A of the GRQ3122-saved preset will also
be copied to the B-output for the GRQ3121 destination unit. For the parameters of the GRQ3121 unit
that can be set independently (i.e., output gain, bypass settings, and delay) for the two outputs, the
original preset values will be loaded, and can differ for outputs A and B.

In the opposite case, when a GRQ3121 preset is being loaded into a GRQ3122, both channels will be
set to the identical values, except for output gain, bypass, and delay — which will reflect the possible
differences in the settings in the loaded file.

8.6.2. Contact Closure Switch Recall

By wiring and connecting a contact closure switch to the rear panel of your Graphi-Q2 (using the
accompanying Euro-block connector), and assigning presets to switch positions using the GRQ Remote
Software, you can create enough configurations to load all possible internal Graphi-Q2 presets.

8.6.2.1. Contact Closure Switch Wiring

Switch wiring requires an 9-conductor cable. Attach these 8 conductors to the 9-pin Euro or Phoenix block
connector included with your
purchase of the Graphi-Q2. This
connector plugs into its mate in
the back of the Graphi-Q2 chas-
sis. The far left pin (as you look
from the back) of the connection
is the ground (common). The
other end of the cable must be
wired such that switch position
one grounds pin one, position
two grounds pin two, etc.