Operation

7

UPS3110 Rack-mountable Series, See Figure 2-5 below, contains the following:

1. AC power cord, fuse holder and input receptacle (17).

2.

INPUT PRESSURE

port (16), 7/16-20, 37

o

-4 AN male fitting. Location of port for AC only units.

NOTE: The maximum input pressure, supplied by user, is noted below port.

3. The unit’s identification plate (15).

4.

VENT/VACUUM PORT

(19), 7/16-20, 37

o

-4 AN male fitting.

5. Optional if required items:

Connector J1 (14), 5 pin round MS style connector, for Serial or Analog Output communication board or

location of

Input Pressure

port for models with battery.

Connector J2 (18), 5 pin round connector, for the Freeze Mode Cable.

NOTE: For further information, see “Options, Replacement Kits” on page 54.

Figure 2-5. UPS3110 Rack-mountable Pressure Calibrator Rear View

UPS3210 Rack-mountable Series, See Figure 2-6 on page 8, contains the following:

1. AC power cord, fuse holder and input receptacle (17).

2.

INPUT PRESSURE

port J3 (16), 7/16-20, 37

o

-4 AN male fitting.

NOTE: The maximum input pressure, supplied by user, is noted above port.

3. The unit’s identification plate (15).

4. Optional if required items:

Connector J1 (14), 5 pin round MS style connector, for Serial or Analog Output communication board.

Connector J2 (18), 5 pin round connector, for the Freeze Mode Cable.

Connector J4, located below identification plate, required for APC4000/APC4001 interface cable.

NOTE: For further information, see “Options, Replacement Kits” on page 54.