14 panel gauge removal, 15 panel gauge installation, Panel gauge removal – Condec UPS3210 User Manual

Page 42: Panel gauge installation

Advertising
background image

38

UPS3000/UPS3110/UPS3210 Operation and Maintenance Manual

NOTE: If pressure cannot be attained loosen locknut on shaft, rotate knob a few turns counter-clockwise, retighten
locknut. If you hear the pressure relief valve then rotate regulator knob counter-clockwise until relief valve shuts off.

11. Remove locknut from threaded shaft, and rotate knob counter-clockwise until bottoming out on large

locknut. After touching large locknut rotate knob clockwise 1/8 turn. Hold knob in position, install and
tighten the locknut with 40 - 50 in-lbs of torque using a 1/2" socket.

12. Open

PRESSURE LIMIT MONITOR

completely, by turning regulator knob clockwise. If you reach between

100-105% of Full Scale and pressure relief valve was not disturbed regulator has been adjusted properly.

13. Replace regulator knob cap.

4.2.14

Panel Gauge Removal

Tools required: Phillips screwdriver

7/16" Wrench

9/16 " Wrench

NOTE: Call CONDEC for replacement Part No.’s.

1. Remove cover from its enclosure as described in Section 4.2.1 on page 28, and carefully place on a

bench top.

2. Disconnect the tubing section that connects to the gauge fitting.

3. Loosen the two thumb-nuts that hold the gauge mounting U-clamp.

4. While gripping the square portion of the gauge port with the 9/16" wrench, remove the Female Tube

Connector (PN 59721) from the Gauge.

5. Remove the two thumb-nuts, the mounting U-clamp, and the gauge.

4.2.15

Panel Gauge Installation

Tools required:

Phillips screwdriver
7/16" Wrench
9/16" Wrench
A/R 1/4" wide Teflon tape (PN 60575)
Snoop, liquid leak gas detector (PN 64781)

NOTE: Call CONDEC for replacement Part No.’s.

1. Before installing a new gauge, wrap two layers of new Teflon tape on the port.

2. Install Gauge into panel, secure with U-clamp and tighten the two thumb screws.

3. While gripping the square portion of the gauge port with the 9/16" wrench, tighten the Female Tube

Connector (PN 59721) on to the gauge.

4. Attach the tubing section that connects to the gauge fitting.

5. Using a pressure source set input pressure to approximately 100% of Full Scale rating of UPS3110 and

check all fittings for leaks.

6. Install cover on its enclosure as described in Section 4.2.1 on page 28.