5.8 LIQUID FERTILIZER APPLICATION RATES


JOHN BLUE

®

PUMP


Perform the following steps to
ensure that the liquid fertilizer
pump is calibrated properly:

1. Set the pointer, 1 FIG. 18,

on the metering pump to a
setting that corresponds
to the desired liquid
application rate.


2. Before

seeding,

accurately measure or
carefully estimate the
amount of liquid in the
liquid fertilizer tank and
note the beginning area
reading on the monitor
display.


3. Seed a significantly large

area. Stop and again
measure or estimate the
amount of liquid remaining
in the tank and note the
area covered.

4. Use the following formula

to calculate the
application rate:









5. Adjust, if necessary, the

pump setting and repeat
the above procedure to
confirm application rate.

1

Tank Level (initial) - Tank Level (final)


Area (final) - Area (initial)

= Application Rate: gal/ac (L/ha)