Ft5000 u – Triton FT5000 User Manual User Manual

Page 98

Advertising
background image

7 8

M

ODEL

FT5000 U

SER

M

ANUAL

F

ACTORY

D

EFAULT

: N/A

A

CCESS

I

NSTRUCTIONS

:

1.

From the MAIN MENU screen,
select the DIAGNOSTICS option
by pressing number (2) on the
keypad.

2.

Enter the DISPENSER diagnos-
tics menu by pressing number
(4) on the keypad.

3.

To modify the CASSETTE PA-
RAMETERS, press number (8)
on the keypad.

4.

To view or change the MUL-
TIPLE AMOUNT in the Active
Cassette, press number (7) on
the keypad.

M

ULTIPLE

A

MOUNT

D

ESCRIPTION

:

The M

ULTIPLE

A

MOUNT

parameter must be set in the ATM before any transactions

can be processed. This number is the denomination of the currency installed in the
currently selected (active) cassette. It can be set to any value, as long as this value
is no less than 1/50th of the maximum cash parameter. Typical values might be 10, 20,
50, or 100.

Whenever a withdrawal transaction is performed, the amount entered or selected is
compared to the Multiple Amount parameter. If the entry is not an even multiple of
this amount, an error warns the customer of this fact and they are offered an oppor-
tunity to try again.

If the Multiple Amount is not set correctly, the terminal will respond by going into
Configuration Error 186, BILL SIZE NOT CONFIGURED CORRECTLY. To correct
the error condition, enter the Management Functions and configure the bill size
(Multiple Amount) to the value of the bill in the cassette.

Select a cassette using the A

CTIVE

C

ASSETTE

function. Press number (7) on the

keypad to bring up the data entry dialog. Enter the multiple amount value, observing
the restrictions stated previously. Press Enter to accept or Cancel to exit without
changing the current amount. The value you enter will be applied to the currently
selected cassette.