RT‐10 Flow Monitor

 

Operation and Programming Manual 

 

 

 

19 

      
 

Frequency Scaling (option) 

 

Will not display if model does not include fiber‐optic frequency output.  

The display (briefly) shows “Fibout” followed by the current programmed Frequency Scaling value. This 
scaling variable is used to set the maximum output of 100 Hz to a corresponding rate value. This 
produces an output ranging from 0 Hz for a zero value to 100 Hz for the programmed flow rate. The 
default initial value is 100.000 (Hz by default K‐factor). Enter the variable directly in the engineering 
units dictated by the K‐factor and Rate Time Base.  

Example:  

 K‐factor entered in pulses per gallon 
 Time base programmed for 60 Sec 
 Enter 20.000 for 100Hz = 20 GPM 

When editing the Frequency Scaling variable the leftmost digit will blink (cursor). Use SEL to move the 
cursor to the right. The cursor wraps around. Use UP or DN to increment or decrement numerals. Edit 
the decimal point last. Use DN to move the decimal point to the right, UP to move it to the left. When 
the desired value appears, use ENT to store the value, exit programming, and return to the RATE display. 

D ISPLA YS
B RIEFLY

D ISPLA YS
B RIEFLY

EN TER RA TE IN
E- UN ITS PER TIM E
B A SE FO R 1 0 0 HZ

O UTPUT

EN TER TIM E IN SEC ,
FO R UPD A TE O F
D ISPLA Y A N D

A N A LO G.

FIB ER- O PTIC (FREQ .)

O UTPUT SC A LIN G

GA TE TIM E (UPD A TE) FO R RA TE

TIM E B A SE FO R RA TE

EN T

EN T

EN T

SEL

EN T

HO LD
3 SEC .

HO LD EN T

EN T

1 SEC

1 SEC

1 SEC

EN T

SEL

SEL

SEL

TO TO TA L

D ISPLA Y

M O D E

D ISPLA YS
B RIEFLY

1 SEC

M O D E

FRO M C LO C K O R TO TA L D ISPLA Y