Product description – AW Gear Meters RT-10 User Manual

Page 6

Advertising
background image

RT‐10 Flow Monitor

 

Operation and Programming Manual 

 

 

 

      
 

 Product Description 

The battery‐powered RT‐10 has a large, six‐digit LCD display that continuously shows either the flow 
rate or total in any engineering units. Program rate, total, reset, sleep mode, or time using buttons 
when the protective blue cover is open, or with a magnet wand when the cover is closed. You can 
also reset the totalizer, and monitor flow rate limits and total output remotely via a computer or PLC.  

The unit’s battery lasts as long as four years and is replaceable on‐site. A variety of sensor options 
make the RT‐10 flow monitor compatible with most meters available from AW Gear Meters, 
including the JV and HPM series positive displacement flow meters, and the TW, TRG and THM 
turbine meters. (Not compatible with the JVHS, JV‐01, JV10 or JV‐12 flow meters.) 

Options include a loop‐powered 4‐20 mA rate output, fiber‐optic input,

 

and a scaled fiber‐optic 

frequency output. (See page 8.) 

Features 

 Gate time function 
 Real‐time clock display 
 Reverts to sleep mode to conserve battery 
 “Sleep” and “Lo Battery” indicators 
 4‐20 mA loop power output 
 Displays Total and Rate values in engineering units such as cc’s, ounces or gallons 
 Easy programming using Up, Down and Enter functions 
 Automatically updates and stores totals in memory every 24 hours  

 

 