5. Specifications

Item

Specification

Remarks

Power supply voltage and
frequency

85 to 264 VAC, 50/60 Hz

100 VAC power cable supplied as
accessory

Power supply capacity

30 VA

Dimensions and mass

120 mm wide

× 200 mm high ×

220 mm deep, 2.7 kg

Operating temperature

0 to 45

°C

Number of programs

4 (Programs 1 to 4)

Programs 1 to 3 are changeable
from external input.

Input module

1. Standard
(1) Electric micrometer
(2) Air micrometer

Changeable by software and
unusable simultaneously:
2 channels for air micrometer
(external) and 2 channels for
electric micrometer (internal)

2. Dedicated for air micrometer

2 channels for air micrometer
(external)

Number of measurement items

3 (Items 1 to 3)

Number of masters

2 (MAS 1 and MAS 2)

Number of input channels
(XDUCER)

4

Air micrometer

1. FS±10

µm (0.05 to 2)

2. FS±20

µm (0.1 to 2)

3. FS±50

µm (0.1 to 2)

4. FS±100

µm (0.1 to 2)

Electric micrometer

1. FS±20

µm (0.1 to 2)

2. FS±100

µm (0.1 to 2)

Indicating range (resolution)

3. FS±1000

µm (1 to 2)

Set for each program.

Resolution is available in six types
of 0.05, 0.1, 0.2, 0.5, 1, and 2.

Mastering data input

Select from among four detectors
A to D (multiple choice possible).
Symbols and coefficients (-9.999
to +9.999) can be freely
combined.

Set for each master.
Example:
MAS 1 = A + B + C
MAS 2 = -A + B

Operation functions

Item 1 can select MAS 1 or MAS
2, Item 2 can select MAS 1, MAS
2, or Item 1, and Item 3 can select
MAS 1, MAS 2, Item 1, or Item 2
(multiple choice possible).
Symbols and coefficients (-9.999
to +9.999) can be freely
combined.

Set for each item.
Example:
Item 1 = MAS 1 + MAS 2
Item 2 = -MAS 1 +MAS 2
Item 3 = Item 1 - Item 2

1. BYPASS
2. +PEAK
3. -PEAK
4. TIR
5. TIR/2
6. MAX
7. min
8. MAX - min
9. (M - m)/2
10. (M + m)/2

Measuring functions

11. ABS

Set for each item.