SHIMPO DEG-2000 User Manual

Page 28

Advertising
background image

26

7.3.8 Ranking output (OK rank 16 or less) –– Output signal arrangement

The ranking output signal is output when “ITEM 1”, “ITEM 2” or “ITEM 3” is selected with
[JUDG OUT], or an item bit is entered in the set mode (6).

Note:

“Item” refers to “ITEM” of DEG2000. The following table shows the output
signal arrangement of the DC input/output connector (refer to ◯

15

on page

7).

Pin No.

Signal name

Description

11

READY

Turns on in measure mode during normal operation.

12

Error

Turns on when two signals are simultaneously input and
turns off when all signals are turned off.

13

Master OK

Turns on when mastering result is OK.

14

Check input signal

Turns on when input signal is received and processing is
completed, and turns off when input signal is turned off.

15

All OK

Turns on at input of measure command when all items
are OK.

16

All NG

Turns on at input of measure command when any one
item is NG.

17

Item -NG

18

+NG

19

OK1

20

OK2

21

OK3

22

OK4

23

OK5

24

OK6

25

OK7

26

OK8

27

OK9

28

OK10

29

OK11

30

OK12

31

OK13

32

OK14

33

OK15

34

OK16

35

-COM

36

-COM

Output common line: 0 V

Advertising