SHIMPO DEG-2000 User Manual

Page 30

Advertising
background image

28

7.3.10 Ranking code output (OK rank 99 or less) –– Output signal arrangement

The ranking code output signal is output when “ITEM 1”, “ITEM 2” or “ITEM 3” is selected
with [JUDG OUT] or an item bit is entered in the set mode (6).

Note:

“Item” refers to “ITEM” of DEG2000. The following table shows the output
signal arrangement of the DC input/output connector (refer to ◯

15

on page

7).

Pin No.

Signal name

Description

11

READY

Turns on in measure mode during normal operation.

12

Error

Turns on when two signals are simultaneously input and
turns off when all signals are turned off.

13

Master OK

Turns on when mastering result is OK.

14

Check input signal

Turns on when input signal is received and processing is
completed, and turns off when input signal is turned off.

15

All OK

Turns on at input of measure command when all items
are OK.

16

All NG

Turns on at input of measure command when any one
item is NG.

17

Item -NG

18

+NG

19

OK1

20

OK2

21

OK4

22

OK8

23

OK16

24

OK32

25

OK64

“OK1” to “OK64” shown at left are ranking codes.
Total of ranking codes is number of ranks.
Example: When “OK2” and “OK4” are turned on, OK6.

26
27
28
29
30
31
32
33
34
35

-COM

36

-COM

Output common line: 0 V

Advertising