SHIMPO DEG-2000 User Manual

Page 26

Advertising
background image

24

7.3.6 Three-item judgment result output –– Output signal arrangement

The three-item judgment result output signal is output when “ALL ITEM” is selected with
[JUDG OUT] in the set mode (6).

Note:

“Item” refers to “ITEM” of DEG2000. The following table shows the output
signal arrangement of the DC input/output connector (refer to ◯

15

on page

7).

Pin No.

Signal name

Description

11

READY

Turns on in measure mode during normal operation.

12

Error

Turns on when two signals are simultaneously input and
turns off when all signals are turned off.

13

Master OK

Turns on when mastering result is OK.

14

Check input signal

Turns on when input signal is received and processing is
completed, and turns off when input signal is turned off.

15

All OK

Turns on at input of measure command when all items
are OK.

16

All NG

Turns on at input of measure command when any one
item is NG.

17

Item 1 -NG

18

-OK

19

OK

20

+OK

21

+NG

22

Item 2 -NG

23

-OK

24

OK

25

+OK

26

+NG

27

Item 3 -NG

28

-OK

29

OK

30

+OK

31

+NG

32
33
34
35

-COM

36

-COM

Output common line: 0 V