- 10 -

The dark square is the direction
the dipswitch should be set to.

EXHAUST

INLET

1
2
3
4
5
6
7
8

TMP1
TMP2
TMP3
MODE
DIRE

OUT

D-PRT

MST

O N

DIRECT INTAKE VENT SYSTEM

This T-M32 water heater may be converted to a direct vent (sealed combustion) appliance by
installing an adapter (Part No. TM-DV32) which will bring all required combustible air from
outside the building. When installing the TM-DV32 conversion kit, please follow all instructions
included with the kit.

• The T-M32 must be installed in a location where the proper amount of combustible air

will be available to it at all times without obstructions.

• If used as a direct vent appliance, the T-M32 requires a 4” combustible air supply pipe.

The intake pipe must be sealed airtight.

• Air supply pipe can be made of ABS, PVC, galvanized steel, corrugated aluminum,

corrugated stainless steel or Category III stainless steel.

• Change the dipswitch settings to the direct vent system. (See diagram below)
• Sidewall venting is recommended for the direct vent system.
• Takagi recommends running the exhaust vent and the intake pipe parallel.
The TM-DV32 Direct Vent Kit has an “INLET” mark as shown below. Do not

reverse the INLET and the EXHAUST connections when installing vent pipes.









TM-DV32 Direct Vent
Conversion Kit

Make sure power to the unit is
turned OFF before changing
the dipswitch settings.

Left Bank of Dipswitches

TM-DV32
DIRECT VENT
CONVERSION KIT

INLET” mark

7-Seg LED

Left bank of
dipswitches

Right bank of
dipswitches