Takagi T-M32 User Manual

Page 32

Advertising
background image

- 32 -

*To change the TM-RE30’s mode from Default Mode to High Temperature Mode, please follow
the procedures below (the TM-RE30 must be installed prior to operating these procedures):

DO NOT set to 185ºF if you use your T-M32 in a recirculation system.

This will cause damage to the heater and void the warranty.




1. Turn off power to the TM-RE30 by pressing the “ON/OFF" button.




2. Simultaneously press and hold both the “HOT” and “COLD” buttons for at least five seconds.
And then make sure “1” (or “0”) is displayed on remote controller.
“1” is displayed for single units “0” is displayed for Easy Link / Multi-Systems



3. Press the “TIME” button.
Make sure OFF and F1 are displayed on remote controller.




4. Press the “INFO” button. After, make sure “OFF” blinks.






5. Press the “HOT” button or the “COLD” button to set display to “on”.






6. Simultaneously press both the “BUZZER” button and the “INFO” button to fix the setting.
7. Make sure display is no longer blinking.






8. Press the “ON/OFF” button to finish the setting.
9. Turn on power to the TM-RE30 by pressing the “ON/OFF” button again.



Blink

Lamp is OFF to indicate that power is off

Blink

Not blinking

Lamp is ON