EASY LINK SYSTEM

The T-M32 can be connected with other T-M32’s with communication cables to work as a
multiple manifold system.

• The Easy Link system can connect up to 4 units.
• A communication cable (gray color) comes with each unit. The cables use 18 gage wire

and can be up to 250ft. long all together.

You can manifold from 2 units to 4 units without a multi-system controller. A 4-unit system has
full automatic modulation between 24,000 BTU/h and 960,000 BTU/h.

• The T-M32 Easy Link system is limited to 4 units. If you connect more than 4

units, the first 4 units will work as part of the Easy Link system, but the other
additional units will only work as individual units.

The T-M32 cannot be linked with other different Takagi

models in the Easy-Link system.

Cold

Hot

Gas

Do not touch the Multi-
System connectors.

To change the dipswitch
settings for the Easy Link
system, locate the left bank
of dipswitches below the 7-
seg LED.
Do not adjust the right
bank of dipswitches.

7-Seg LED

Right bank of
dipswitches

Left bank of
dipswitches

Easy Link connectors
are on each unit’s
computer board.