Takagi T-M32 User Manual

Page 29

Advertising
background image

- 29 -

Temperatures available under the High Temperature Mode

The dark squares indicate the direction
the dipswitches should be set to.

In a Multi-Unit system, connect the

[3] connector

and the

[4] connector

with the

communication cable.





Please refer to the TM-MC01 manual for further instructions of the Multi-Unit system.














Connecting T-M32’s and the T-M1’s together in a

Multi-Unit System


When the T-M32 and T-M1 are connected
together in a multi-unit system to the TM-
MC01, change dipswitch No. 6 on the TM-
MC01 computer board to the “ON” position.

When the T-M32 is connected to the T-M1 as part of the Multi-unit system with the TM-RE10 or
the TM-RE30, you can set the temperature from 99ºF to 167ºF/182ºF as shown below.

NOTE: *The maximum set temperature with the TM-RE10
When the red jumper on the back of the TM-RE10 is installed, the maximum set temperature is 167

°F. If you remove

the jumper, the maximum set temperature will be 182

°F.

When the set temperature is 182

°F, “H” is displayed on the TM-RE10.

*Refer to p.31 about the TM-RE30.

99

100

102

104

106

108

110

111

113

115

117

122

131

140

158

167

99

100

102

104

106

108

110

111

113

122

131

140

149

158

167

182*

3 4 5 6 7

2

1

O N

8

Dip switch setting on

the TM-MC01

Temperatures available under the Default Mode

T-M32 Comunication Cables are included
with the T-M32. The Cables use 18 gage
wire and can be up to 250 ft. long.

Wire

[3]

(Male Adapter) and

[4]

(Female Adapter)

Multi-unit connectors are
on each unit’s computer
board.

7-Seg LED

Right bank of
dipswitches

Left bank of
dipswitches

Do not touch the Easy Link
connectors.