VENT CLEARANCES

























Canada U.S.A

Direct vent and

other than Direct

Vent

Direct vent

Other than Direct Vent

A

Clearance above grade, veranda, porch,
deck, or balcony.

1 foot

1 foot

1 foot

B

Clearance to window or door that may be
opened.

3 feet

1 foot

4 feet from below or

side opening. 1 foot

from above opening.

C

Clearance to permanently closed window

*

*

*

D

Vertical clearance to ventilated soffit
located above the vent terminator within a
horizontal distance of 2 feet (61cm) from
the center line of the terminator.

* *

*

E

Clearance to unventilated soffit

*

*

*

F

Clearance to outside corner

*

*

*

G

Clearance to inside corner

*

*

*

H

Clearance to each side of center line
extended above meter/regulator assembly

3 feet

*

*

I

Clearance to service regulator vent outlet.

3 feet

*

*

J

Clearance to non-mechanical air supply
inlet to building or the combustion air inlet
to any other application.

3 feet

1 foot

4 feet from below or

side opening. 1 foot

from above opening.

K

Clearance to mechanical air supply inlet.

6 feet

3 feet

3 feet

L

Clearance above paved sidewalk or
paved driveway located on public
property.

7 feet

*

7 feet

M

Clearance under veranda, porch deck, or
balcony.

1 foot

*

*

*For clearances not specified in ANSI Z223.1 / NFPA 54 or CAN/CSA-B149.1, please use clearances in
accordance with local installation codes and the requirement of the gas supplier.