Electrical connections – Takagi T-M32 User Manual

Page 19

Advertising
background image

- 19 -

ELECTRICAL CONNECTIONS

WARNING: Follow the electrical code requirements of the local authority having
jurisdiction. In the absence of such requirements, follow the latest edition of the
National Electrical Code ANSI/NFPA 70 in the U.S. or the latest edition of CSA
C22.1 Canadian Electrical Code, Part 1, in Canada.

CAUTION: When servicing or replacing parts within the T-M32, label all wires prior to
disconnection to facilitate an easy and error free reconnection. Wiring errors can cause
improper and dangerous operation. Verify proper operation after servicing.

1.

The heater must be electrically grounded. Do not attach the ground wire to either the gas
or the water piping.

2.

The Mobius T-M32 water heater requires AC 120V 60 Hz electrical power supply that
is properly grounded.

• A proper disconnect (i.e. on/off switch, power plug, etc.) controlling the main power to

the T-M32 must be provided for service reasons. (Must comply with local codes).

• Connect the power supply to the T-M32 exactly as shown in the wiring diagram;

3.

A green screw is provided in the junction box to ground the connection.

4.

Can be hardwired or wired to a plug-in.

5.

The use of a surge protector is recommended in order to protect the unit from power
surges.

Ground

Connect Power supply

AC120V 60Hz