Operator panel, 2 operator panel – Avery ALS 330/430 User Manual

Page 15

Advertising
background image

Operators Manual

ALS 330/430

Release 4/06

Page 13

Description

2.2 Operator panel

The operator panel (Figure 2) of the 330/430 is shown below, it has a 4 digit LED display and 4
membrane keys.

Figure 2 Operator panel

The 4 membrane keys have following functions:

FEED:

By pressing this key one label will be dispensed. When the machine

displays INIT pressing this key will start initialisation of the machine. An
initialisation has to be made each time a new material is used. If the FEED key is
pressed and held as the machine is turned on then the machine carries out an
automatic initialisation of the label parameters "CONT" and "LPIT".

PRIOR:

This key moves up the menu or increases the value of a (Prior function)

parameter. If the up arrow key is pressed and held as the machine is turned on
the product menu is selected.


NEXT:

This key moves down the menu or decreases the value of a (Next

function) parameter. If the down arrow key is pressed and held as the machine is
turned on the standard menu is selected.