Signals for the ep applicator, Operators manual, 3 signals for the ep applicator – Avery ALS 330/430 User Manual

Page 66

Advertising
background image

Operators Manual

ALS 330/430

Release 4/06

Page 58

Connections and signals

8.2.3

Signals for the EP applicator

For controlling the applicator the signals air stream, cylinder valve and blow on are necessary.
After a product signal has occurred the labelling cylinder valve is switched active after the delay
STAD. However if at this time the applicator is not in the home position then error message
E__2 is generated. After the delay time APT1 the blow on valve is switched active for the time
APT2.
When APT2 is completed both the labelling cylinder valve and the blow on valve signals are
switched inactive. If the control does not read the home position in the time given - 3* (APT1+
APT2) - than the error message E__2 is generated.

Productstart

Cylinder valve

Dispense label
+ Airstream valve

Blowon valve

Homeswitch

1

2

Missing Label: Labeller not ready for dispense

Error: Applicator not in homeposition

3

Error: Homeposition not detected

STAD

APT1

APT3

APT2

1

3

STAD

STAD

APT1

4 * (APT1 + APT2)

STAD

2

Figure 19 Timing EP applicator

Advertising