Errors and warnings

Message

Meaning

How to solve

set to the factory adjustment.

E__5

10V supply voltage for label
sensor low.

Short circuit in label sensor or cable.
Voltage regulator U14 is damaged.

E__6

24V Voltage low

Short circuit on an output. Total load too
high i.e. max is 3A for all outputs.
Voltage regulator U1 is damaged.
Change main board.

E__7

Material initialization failed

Check if the label web is threaded
through the label sensor

E__8

Error stepper motor driver

The stepper motor control has detected
an error. The fault is indicated by the
LED’s on the driver.

E__9

10V supply for label sensor too
high

Voltage regulator U14 damaged

E__10

Missing label on product

One or several product could not be
labelled. Distance between products too
close. Increase speed of printer.

___0

Process error (Divide overflow)

Hardware failure external noise. EPROM
damaged. Turn off power and on again.
Change EPROM or main board

___1

Illegal interrupt (processing error)

Hardware failure external noise. EPROM
damaged. Turn off power and on again.
Change EPROM or main board

___2

Illegal bank interrupt (processing
error)

Hardware failure external noise. EPROM
damaged. Turn off power and on again.
Change EPROM or main board

INTO

Illegal interrupt INTP0 (processing
error)

Hardware failure external noise. EPROM
damaged. Turn off power and on again.
Change EPROM or main board.