5.2 Extended standard menu

The extended standard menu offers additional parameters you may use in your application. On
quitting this menu the current parameter settings are stored in memory. Further changes are
also written into memory. As long as this menu is active, no labelling is possible. By pressing
the key FEED, however, single dispense of labels is possible.
To get into the extended standard menu a password CODE has to be entered. The display
shows the first menu point. A survey of all parameters is shown below.

Display Function

Data

value

LPIT

Label pitch

AUTO/5...999 mm

CONT

Label sensor contrast value

AUTO/1...200

SENS

Sensor status

LAB or GAP

STOD

Stop position of label at the dispensing edge

0.0 .... 200.0 (mm)

PRDL

Product length (inhibit of further product- sensor
signals)

AUTO, 5 ... 999 mm

POS

Position of label on product

Up to 999.9 mm

STAD

Delay time for start of applicator cycle

1 ... 9999 ms

VELO

Labelling speed

0.2 ... 30 m/min

STST

Check adjusted EGRA value

see text

SLEW

Slew speed

FAST or SLOW

EGRA

Electronic gear ratio adjustment

100 to 500

APT1

Dwell time for applicator

1 ... 7500 ms

APT2

Blow on time for applicator

1 ... 7500 ms

APT3

Restart delay

0 ... 5000 ms

APT4

Time constant compensation

0 ... 500 ms

ASTP

End of air stream signal

-20 ... 50 mm

PDT

Printer dwell time

OFF - 1000ms