Dispenser warnings, Dispenser error messages, 2 dispenser warnings – Avery ALS 330/430 User Manual

Page 83

Advertising
background image

Operators Manual

ALS 330/430

Release 4/06

Page 75

Errors and warnings

9.2 Dispenser warnings

In case of a warning message the relevant output is switched. The signal can be used for
interconnection with an external machine control. Warning W__5 activates only the special OD
warn output.

Message

Meaning

How to solve

W__0

New start signal from
product sensor while
ALX720 is dispensing a
label
Multiple signals from the
same product
Several missing labels on
the web, which can not be
compensated

Slow down conveyor speed or
product sequence.
Adjust higher labelling speed
Increase the parameter value
of PRDL product length

W__2

Error while writing in the
EEPROM

EEPROM defect, Start
machine again, if problem
remains the same, exchange
EEPROM as soon as possible

W__3

RS232 transfer error

Check interface parameter in
the configuration menu and in
the host

W__4

Conveyor speed exceeded
the max. speed of the
dispenser

Slow down conveyor. If
average conveyor speed is OK
then check for oscillation in the
conveyor speed or vibration of
the pulse generator

W__5

Material end by the OD
control recognised

Insert a new material roll

W__6

Too many products between
sensor and dispensing edge

Move the sensor closer to the
dispensing edge













Advertising