Input signals, 3 input signals, Operators manual – Avery ALS 330/430 User Manual

Page 68

Advertising
background image

Operators Manual

ALS 330/430

Release 4/06

Page 60

Connections and signals

8.3 Input signals


This machine (dispenser) is provided with photo coupled inputs for:

y

the product sensor signal

y

an inhibit signal for inhibiting labelling

y

a signal from an OD control which shows the end of the material roll.

y

a signal from an automatic product speed follower

y

the EP applicator signals from the HOME and END switches

y

an unused input for future extensions or customer specific software (used for loop control in
the 720)

The inputs are galvanically separated through photo couplers to connect to PNP or NPN
outputs. The wiring and the connection of the signal plug is shown otherwise. The input voltage
across the inputs must be in the range of 15 V to 30 V to switch active.

ln+

Signal

ln-

Machine

(alternative switch)

+24V DC

NPN

Opto-
isolator

2K2

ln+

Signal

ln-

Machine

(alternative switch)

+24V DC

PNP

Opto-
isolator

2K2

Figure 21:

Connecting NPN (left) or PNP (right) inputs.