Serial interface

#!SR__

The machine is set to on. The product sensor is enabled and labelling can
restart.

For a full automatic operation, the following procedure in case of an error is required:

y

#!ERRF

Request

error

y

#!CLRE

Clear error message after fixing the error. The labeller shows „INIT“

y

#!SR__

Clear INIT message

Bit definition in error flag
Error number Error message in display

Error description

0

E__0

Pressure roller open

1

E__1

End of material (4 missing labels)

2

E__2

EP-applicator error

3

E__3

checksum error configuration data

4

E__4

checksum error parameter bank

5

E__5

Error 10V low

6

E__6

Error 24V low

7

E__7

missing label on product

8 E__8

Error

motor

driver

Bit definition in warning flag
Warning

Message in display

Warning description

0

W__0

Next product start before finished

1

W__1

Product start but no material not initialised

2

W__2

EEPROM error during write

3 W__3

Interface

warning

4

W__4

APSF speed too fast

5

W__5

End of material (OD-Control)

6

W__6

too many products

7

W__7

Loop not ready (720)