Connections and signals

8.3.1 Product

sensor

The product sensor starts the labelling. The source of the signal could be a optical sensor, a
switch or a signal from a PLC. The time between start signal and start of dispensing (adjusted
with POS) should be as small as possible. This means that an optical sensor should be placed
10 to 20 mm before the dispensing edge. The minimum distance is necessary for the internal
speed compensation.
The machine is supplied as standard with one socket for connecting the product sensor. You
may either use a NPN or PNP type sensor output.

+24V

GND

13

black

blue

white

red

brown

5
9
4
8
3
7
2
6

1

Signal-

GND

Signal+

Supply

white

black

blue

26

34

27

CN33

S5-5-C8-30

NPN-Sensor

5
9
4
8
3
7
2
6

1

Figure 22 Example for connecting an NPN sensor (Datalogic)

+24V

GND

13

black

blue

white

red

brown

5
9
4
8
3
7
2
6

1

Signal-

GND

Signal+

Supply

white

black

blue

26

34

27

CN33

S5-5-C8-30

PNP-Sensor

5
9
4
8
3
7
2
6

1

Figure 23 Example for connecting an PNP sensor (Datalogic)